next up previous contents
Next: OPTIONS command Up: Command descriptions Previous: NOISE command   Contents

Subsections


OP command

Syntax

OP start stop stepsize {options ...}

Purpose

Performs a nonlinear DC steady state analysis, with no input. If a temperature range is given, it sweeps the temperature.

Comments

There are substantial extensions beyond the capabilities of the SPICE op command.

If there are numeric arguments, they represent a temperature sweep. They are the start and stop temperatures in degrees Celsius, and the step size, in order. They are saved between commands, so no arguments will repeat the previous sweep.

This command will use the op probe set, instead of automatically printing all nodes and source currents, so you must do "print op ...." before running op. We did it this way because we believe that printing everything all the time is usually unnecessary clutter. All of the information available from SPICE and more is available here. See the print command and the device descriptions for more details.

A single parameter represents a single temperature. Two parameters instruct the computer to analyze for those two points only.

This command also sets up the quiescent point for subsequent AC analysis. It is necessary to do this for nonlinear circuits. The last step in the sweep determines the quiescent point for the AC analysis.

Options

* multiplier
Log sweep. Multiply the absolute temperature by multiplier to get the next step. The fact that it is offset to absolute zero may make the step sizes look strange.

> file
Send results of analysis to file.

» file
Append results to file.

BY stepsize
Linear sweep. Add stepsize to get the next step.

Continue
Use the last step of a OP, DC or Transient analysis as the first guess.

Input volts
Apply volts input to the circuit, instead of zero.

LOop
Repeat the sweep, backwards.

PLot
Graphic output, when plotting is normally off.

Print
Send results to printer.

Quiet
Suppress console output.

REverse
Sweep in the opposite direction.

TAble
Tabular output. Override default plot.

TEmperature degrees
Temperature, degrees C. Override the sweep.

TImes multiplier
Log sweep. Multiply the absolute temperature by multiplier to get the next step.

TRace n
Show extended information during solution. Must be followed by one of the following:
Off
No extended trace information (default, override .opt)
Warnings
Show extended warnings
Iterations
Show every iteration.
Verbose
Show extended diagnostics.

Examples

op 27
Do a DC operating point simulation at temperature 27 degrees Celsius.

op -50 200 25
Sweep the temperature from -50 to 200 in 25 degree steps. Do a DC operating point simulation at each step.

op
With no parameters, it uses the same ones as the last time. In this case, from -50 to 200 in 25 degree steps.

op 200 -50 -25
You can sweep downward, by asking for a negative increment.

op Input 2.3
Apply an input to the circuit of 2.3 volts. This overrides the default of no input.

op TEmperature 75
Simulate at 75 degrees, this time. This isn't remembered for next time.

op
Since the last time used the TEmperature option, go back one more to find what the sweep parameters were. In this case, downward from 200 to -50 in 25 degree steps. (Because we did it 3 commands ago.)


next up previous contents
Next: OPTIONS command Up: Command descriptions Previous: NOISE command   Contents
Al Davis 2002-03-26